Power/ Video/ Data UTP Transceiver |
 |
|
 |
 |
|
| |
The unparalleled interference rejection and low emissions of the PVD Transmission system allows video and low-voltage power to coexist within the same 4-pair cable, using structured (EIA 568B) wiring practices.
The Model PTX-120VP and PTX-100PVD Video Transmitter +12VDC Converter is a passive (non-amplified) video transmitter combined with a DC40-12V / AC28-24V-to-12VDC converter. Designed to fit on the back of a fixed 12 VDC camera, this unit is architected to convert DC40-12V / AC28-24V power from the control room (DVR Site), while use with PRX-400PVD or PTX-120VP delivering real-time composite (Base-band) video signals and power at extended distances, all over one 4-pair UTP cable.
The Passive Video Receiver Hub PRX-400PVD or PTX-120VP on the control room (DVR Site), which allow DC40V / 28VAC/ 24VAC inputs that can support at-distance camera loads up to 0.5 Amp for cable runs under 1000ft (300m). The PVD transmission system builds in diagnostic LED display load/no-load at a glance and surge protection, damaging voltage spike problems are eliminated. |
|
 |
 |
Specification |
 |
|

| Model/ Item |
|
PTT-100VP |
|
PRX-120VP |
|
PTX-120VP |
|
PRX-400PVD |
|
PTX-100PVD |
| Connector |
|
BNC & Terminal block |
|
BNC & RJ45BNC & Terminal block |
| Communication Type |
|
Transceiver |
|
Receiver |
|
Transmitter |
|
Receiver |
|
Transmitter |
| Signal |
|
Video/ Power/ Data |
| Wire Cable |
|
UTP Category 2 or better cable UTP 24-16 AWG (0.5-1.31mm) |
| Impedance |
|
BNC: 75Ω; Terminal Block: 100 Ω |
| Frequency response |
|
DC to 5 MHz |
| Insertion Loss (Video) |
|
Less than 2 dB /pair over the frequency from DC to 5 MHz |
| Return Loss(Video) |
|
Greater than 15 dB over the frequency from DC to 5 MHz |
| Common/Differential Mode Rejection |
|
None |
|
60 dB @15 KHz to 5 MHz |
| Output Power |
|
|
|
None |
|
DC 12V |
|
None |
|
DC12V |
| Input Current |
|
Max. 1A |
|
None |
|
Max. 2A |
|
None |
| Output Current |
|
Max. 1A |
|
Max. 600 mA |
|
None |
|
Max. 1.5A |
| Max Surge Peak Voltage |
|
None |
|
6KV |
| Max Surge Peak Current |
|
None |
|
150A |
| Surge Protection Time |
|
None |
|
10uS |
| Normal Resistance Cross Coax |
|
None |
|
1000M Ohm |
| Surge Resistance |
|
None |
|
0 Ohm |
| Low Pass Filter |
|
None |
|
1000M Ohm |
| Insertion loss (Surge) |
|
None |
|
3.58M Less than 0.2dB |
| Return loss (Surge) |
|
None |
|
3.58M Less than 0.2dB |
| Environmental |
|
-20℃ 〜 70℃, Humidity: 0 to 95% (non-condensing) |
| Dimension |
|
45x21x15mm |
|
65 x 44 x 26 mm |
|
215x55x35mm |
|
97x60x35mm |
| Weight |
|
35 g |
|
150 g |
|
500 g |
|
200 g |
|

Note:
1. Tested using the Category 5 UTP cable.
2. It is recommended that the 24VAC/28VAC not share the same jacketed wire bundle with telecom or LAN signals.
3. You must use the DC40V/ AC28V/24V power input for PRX-400PVD when used with PTX-120VP.
4. The Transmission distance of Video, please refer to the video distance Chart. |
|
 |
 |
Accessories |
 |
|
| RMP-219 19 inches Rack Mount Panel |
 |
Allow 2 sets of 4 ports EZlink devices in 1 U high of 19"cabinet. |
 |
Combine with 4 ports EZlink devices flexibly. |
 |
Maintain easily with modularized design. |
 |
Save maintenance costs by swapping 4 ports module |
| RMP-319 19 inches Rack Mount Panel |
 |
Allow 3 sets of PS2804-AC devices in 1 U high of 19"cabinet. |
 |
Maintain easily with modularized design. |
|
 |
| 4 Ports Power Distributing Box |
 |
One DC11-15V in and four DC11-15V out. |
 |
Build in power noise filter. |
 |
Save power plug space. |
 |
Save power adapter cost. |
 |
LED indicator shows power status. |
|
 |
| YU Connector |
 |
Tool less design; easy to use and maintain |
 |
Low connection loss |
|
 |
 |
Application Configuration |
 |
|


 |
 |
|
 |
|