ParkSen® Zone Controller
The ParkSen® PSC-064 Zone Controller is a groundbreaking solution for smart parking systems. Its decentralized architecture and support for both RS-485 and LAN connections offer greater flexibility and stability than traditional central controllers. This design can reduce wiring costs by an average of 25%. Each PSC-064 can connect to 64 PS-200A ultrasonic detectors, gathering real-time data on occupancy and device status. It communicates directly with the ParkHelper® Parking Management Host, enabling efficient guidance and management. Features such as online configuration and automatic fault detection make it a reliable and cost-effective choice for any smart parking system.
Key Features

Decentralized Architecture
This next-generation system features a highly optimized and integrated architecture. By incorporating all the logic functions and hardware of a central controller into a decentralized design, it eliminates the need for a central control unit, effectively reducing system failure rates and maintenance costs.

Dual Interface Transmission
Supporting both RS-485 and LAN interfaces, the controller offers greater flexibility in wiring. This new architecture can reduce installation and wiring costs by approximately 25% compared to traditional systems.

Remote Setup and Management
The PSC-064 integrates online configuration, testing, calibration, and automatic fault isolation. This allows for remote adjustment of system parameters via the network.

High Connection Capacity
Each PSC-064 Zone Controller can connect to 64 PS-200A ultrasonic detectors. It collects and forwards status data from all detectors, including occupancy, connection status, and detector and display light operation.
Schematic diagram

Wiring diagram

Technical Specifications
| Detection Items | Detects parking space status, detector operation, and light status. Includes automatic fault isolation. |
| Connected Detectors | Supports up to 64 PS-200A ultrasonic detectors. |
| Parking Space Info | Transmits regional or floor parking information to the parking management host via RS485 or RJ45 network for display on LED signs. |
| Devices | Unlimited number of controllers can be connected via a LAN. |
| Communication Protocol | RS485: Half-duplex, 4800 BPS baud rate. LAN: 100Base-T for data transmission to the host. |
| Communication Distance | ≤1200 meters (RS-485) | 100 meters (LAN) |
| Certifications | CE, FCC, RoHS, IP55 |
| Housing | Full-metal anti-interference design |
| Size/Weight | 235mm (W) x 272mm (L) x 68mm (H) | 1.85 Kg |
| Power | 100~240VAC/ 50~60HZ input; DC12V/8A output |
| Operating | Temperature: -20°C to 60°C | Humidity: 10% to 90% (non-condensing) |